(a) A top clearance shall be provided of at least 11 feet above the top terminal landing. Such clearance shall be maintained from a plane through each face of the belt to a vertical cylindrical plane having a diameter of 2 feet greater than the diameter of the floor opening, and extending upward from the top floor to the ceiling on the up-running side of the belt. No encroachment of structural or machine-supporting members within such space is permitted.

(b) There shall be a clearance of at least 5 feet between the center of the head pulley shaft and any ceiling obstruction. The center of the head-pulley shaft shall be not less than six feet above the top terminal landing.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.