Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 7 - ELEVATORS, LIFTS, ESCALATORS, DUMBWAITERS, HOISTS ANDTRAMWAYS
Subchapter G - MANLIFTS
SPECIFICATIONS
Section 7.222 - Floor openings

Universal Citation: 34 PA Code ยง 7.222

Current through Register Vol. 54, No. 38, September 21, 2024

(a) Floor openings for a manlift shall be uniform in size, be approximately circular and be located vertically above the opening below it.

(b) Floor openings for both up and down runs shall conform to the following:

Belt (in inches)Floor Opening Width (in inches)
1228-32
1434-38
1636-40

(c) Floor openings shall extend not more than 24 inches nor more than 28 inches from the face of the belt.

This section cited in 34 Pa. Code § 7.223 (relating to landings).

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.