Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 7 - ELEVATORS, LIFTS, ESCALATORS, DUMBWAITERS, HOISTS ANDTRAMWAYS
Subchapter F - POWER-OPERATED SPECIAL INDUSTRIAL SERVICE ELEVATORS
SPECIFICATIONS
Section 7.187 - Guide rail construction

Universal Citation: 34 PA Code ยง 7.187

Current through Register Vol. 54, No. 38, September 21, 2024

(a) Car and counterweight guide rails shall be constructed of steel or wood. If wood is used it shall be maple or equivalent and of not less than 1-1/2 by 2 inches.

(b) Guide rails shall be securely fastened, in accordance with the following:

(1) Guide rails and their fastenings shall not deflect more than 1/4 inch under normal operation.

(2) Joints of guide rails shall be well-fitted and strongly secured.

(3) Guide rails and their joints and fastenings shall withstand the application of the safety when stopping the fully-loaded car.

(c) Guide rails shall extend from the bottom of the hoistway to a height above the top landing sufficient to prevent the guide shoes from running off the guides when the car or counterweight is at the extreme upper position.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.