Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 7 - ELEVATORS, LIFTS, ESCALATORS, DUMBWAITERS, HOISTS ANDTRAMWAYS
Subchapter E - PERSONAL SERVICE ELEVATORS
SPECIFICATIONS
Section 7.153 - Limit switches
Universal Citation: 34 PA Code ยง 7.153
Current through Register Vol. 54, No. 38, September 21, 2024
Upper and lower normal stopping devices shall be provided, set to stop the car at the upper and lower terminal landings. Final stopping devices shall be provided and set to operate if the car passes the terminal landings. Such stopping devices shall stop the car before it strikes the overhead or pit bottom. The final terminal stopping device shall act to prevent movement of the car in both directions of travel. The normal and final terminal stopping devices shall not control the same switches on the controller unless two or more separate and independent switches are provided, two of which shall be closed to complete the motor and brake circuit in each direction of travel.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.