Section 7.147 - Guide rail construction
Universal Citation: 34 PA Code ยง 7.147
Current through Register Vol. 54, No. 38, September 21, 2024
(a) Car and counterweight guide rails shall be constructed of steel.
(b) Guide rails shall be securely fastened in accordance with the following:
(1) Guide rails
and their fastenings shall not deflect more than 1/4 inch under normal
operation.
(2) Joints of guide
rails shall be well-fitted and strongly secured.
(3) Guide rails and their joints and
fastenings shall withstand the application of the safety when stopping the
fully-loaded car.
(c) Guide rails shall extend from the bottom of the hoistway to a height above the top landing sufficient to prevent the guide shoes from running off the guides when the car or counterweight is at the extreme upper position.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.