Current through Register Vol. 54, No. 38, September 21, 2024
(a) The cars of new sidewalk power-driven elevators shall be provided with a substantial guard or bow to open and close the sidewalk doors. Constant-pressure key switches on street landings of sidewalk elevators shall be used for the entire control of the elevator within the distance of travel from the sidewalk level necessary to open or completely close the sidewalk doors. Control from the car, lower, or intermediate landings is permitted only within the car travel which does not cause the sidewalk doors to open or close.
(b) The cars of existing power-driven sidewalk elevators shall be provided with a substantial guard or bow to open the sidewalk doors, or the sidewalk doors shall be arranged to open by hand. When a guard or bow is used, substantial removable railings at least 42 inches in height shall be placed at the sidewalk level, constructed, and installed so that the car-controlling mechanism is locked and the elevator car held immovable until the railing is placed in position. A constant-pressure key switch on the street landings of sidewalk elevators may also be used in lieu of guardrails. When doors are to be opened by hand, the controlling mechanism shall be arranged to hold the car immovable while the doors are being opened, and the removable railing may be dispensed with, if other conditions meet the requirements of subsection (c).
(c) Sidewalk protection shall be achieved in accordance with the following: