Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 6 - CONSTRUCTION AND REPAIRS
SPECIFICATIONS
Section 6.23 - Window jack scaffold

Universal Citation: 34 PA Code ยง 6.23

Current through Register Vol. 54, No. 44, November 2, 2024

(a) Use. Window jacks shall be constructed to sustain a working load of 200 pounds with a safety factor of four and shall be used only for the purpose of working at the window through which the jack is placed. The placing of planks between one window jack and a jack in an adjacent window is prohibited. Window jacks shall not act as the supporting elements for other scaffolding.

(b) Persons permitted. Not more than one person shall be permitted to be on a window jack scaffold at any one time.

(c) Approval. Window jacks shall be of an approved type.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.