Section 57.2 - Separation and mixed occupancy
Universal Citation: 34 PA Code ยง 57.2
Current through Register Vol. 54, No. 38, September 21, 2024
When a C-4 occupancy shares a structure with one or more occupancies, the structure shall be governed in one of the following manners:
(1) C-4 occupancies shall be separated from all A-1, A-2, B, C-1, C-3 and C-5 occupancies by fire walls. Each portion thus separated shall be considered a separate building.
(2) C-4 occupancies may be separated from A-3, C-2 and D-O occupancies by fire walls and considered separate buildings, or C-4 occupancies may share a building with A-3, C-2 or D-O occupancies as a mixed occupancy when all of the following conditions are met:
(i) The construction type complies with the
most restrictive limitations of all divisions occupying the building.
(ii) The building size limitations and story
height limitations do not exceed the C-4 requirements.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.