Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 55 - DIVISION C-2 HOTELS, MOTELS, APARTMENT BUILDINGS, ETC
MEANS OF EGRESS
Section 55.21 - Minimum exits

Universal Citation: 34 PA Code ยง 55.21

Current through Register Vol. 54, No. 38, September 21, 2024

(a) There shall be a minimum of two exits reasonably remote from each other. At least 50% of required exits shall be exit discharge doors, stair towers or ramps.

(b) Basements used only for storage or mechanical equipment without any permanent occupancy shall have a minimum of two exit access paths except that the Department may permit a single exit access for basements used only for storage or mechanical equipment without any permanent occupancy of less than 1,000 square feet.

(c) Mezzanine levels shall have a minimum of two exit access paths except that the Department may permit a single exit access from mezzanines less than 1,000 square feet or mezzanines used exclusively for storage or mechanical equipment without a permanent occupancy.

(d) An individual apartment which occupies more than one floor level shall only be required to have an exit from one floor level.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.