Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 55 - DIVISION C-2 HOTELS, MOTELS, APARTMENT BUILDINGS, ETC
CONSTRUCTION TYPE-MAXIMUM STORY HEIGHT
Section 55.11 - Story height

Universal Citation: 34 PA Code ยง 55.11

Current through Register Vol. 54, No. 44, November 2, 2024

(a) C-2 occupancy shall be governed by the story height limitations in the following table:

Construction TypeMaximum Story Height
FireresistiveNo Limit
Noncombustible3 Stories*
Protected Heavy Timber3 Stories*
Ordinary3 Stories*
Wood Frame2 Stories*

(b) *An additional story shall be permitted in noncombustible, protected heavy timber, ordinary or wood frame construction when the building is 1-hour rated construction or totally protected by an automatic sprinkler system. The maximum story height may be increased two stories when 1-hour rated construction and total automatic sprinkler protection are provided.

(c) Noncombustible, protected heavy timber, ordinary and wood frame construction types shall be considered 1-hour rated construction when bearing walls, columns, beams, other supporting members, ceiling/roof assemblies, floor/ceiling assemblies, stairways and other openings through floors are of 1-hour rated construction.

(d) Apartment units shall be separated from each other and all other portions of the building by a minimum of 1-hour rated construction.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.