(a) Submission and approval. Before a building to which Chapters 49-59 apply (except for C-3 occupancies covered under Chapter 56) is erected, adapted, remodeled or altered, detailed architectural plans, wall sections and elevations for new construction remodeling or alteration work and line drawings to scale for all portions of the existing buildings showing means of egress shall be submitted to and approved by the Bureau of Occupational and Industrial Safety, Buildings Section, Department of Labor and Industry, as required under section 8 of the act (35 P. S. § 1228). Drawings shall be submitted in triplicate. In cases where emergency lighting systems, fire alarm systems, or fire extinguishing apparatus is required by this chapter, these requirements shall be completely shown on or with the drawings submitted before approval of the building is obtained.
(b) C-3 occupancies. C-3 occupancies covered under Chapter 56 shall have the following information on file in the Department:
(c) Plan requirements. Plans shall be reproduced on paper prints a minimum of 15" x 24" , and drawn to a scale of not less than 1/8 inch to the foot unless the size of the building is such that it is impossible to contain the entire building on a 42-inch sheet size, in which case drawings may be accepted at a scale 1/16 inch to the foot. They shall show floor plans of all floors, all outside elevations, and location plans (site plan) of all streets or alleys abutting and distances from adjacent or adjoining buildings. Specifications shall also be furnished when requested. Buildings located in a new development shall have their location distinctly shown by lot number or letter on a plot so that they may readily be found by the Department.
(d) Accelerated approvals.
This section cited in 28 Pa. Code §501.81 (relating to safety from fire); 34 Pa. Code § 50.85 (relating to approval of plans); and 34 Pa. Code § 60.3 (relating to submission of plans).