Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 47 - MISCELLANEOUS PROVISIONS
Subchapter I - TEXTILE INDUSTRIES
DYEING AND FINISHING
Section 47.351 - Heating and ventilating
Universal Citation: 34 PA Code ยง 47.351
Current through Register Vol. 54, No. 38, September 21, 2024
(a) The requirements of this section in addition to the requirements of §§ 47.342-47.343 (relating to apparatus; machines) shall be complied with in dyeing and finishing establishments.
(b) Dye houses shall be equipped with ventilating systems which will produce the following conditions:
(1) During the months of
November, December, January, February, March, April and May, the temperature of
the dye house shall be maintained between 40°F and 95°F. During this
period when the weather is clear and the outside temperature is 40°F or
more, the dye house shall be kept free from steam to a height of 6 feet from
the floor. The ventilating system employed to produce this freedom from steam
shall be maintained in operation during less favorable weather
conditions.
(2) During the months
of June, July, August, September and October, the dye house shall be kept free
from steam at all times to a height of 6 feet from floor.
(c) The systems which are used to produce the conditions set forth in subsection (b) may consist of ventilating fans, heating coils, hoods with flues attached over kettles or introduction of hot air on other natural ventilating devices.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.