Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 47 - MISCELLANEOUS PROVISIONS
Subchapter D - FACILITIES FOR HANDICAPPED
GROUNDS, BUILDINGS AND FACILITIES
Section 47.123 - Ramps
Current through Register Vol. 54, No. 44, November 2, 2024
When ramps are required they shall conform to the following specifications:
(1) Each ramp shall have a slope no greater than 1 foot rise in 12 feet of run or 8.33% grade or 4 degrees and 50 minutes deflection.
(2) Each ramp shall have a handrail on at least one side or preferably on both sides. If the width of the ramp exceeds 84 inches, there shall be an intermediate rail in the ramp. The top of handrails shall be 32 inches above the surface of the ramp and extend one foot beyond the top and bottom of the ramp.
(3) Each ramp shall be at least 32 inches wide (inside clear measurements) and have a nonslip surface.
(4) If a door swings out onto the platform or toward the ramp, such ramp shall be at least 5 feet square. This platform shall be clear of the door frame.
(5) If the door does not swing on to the platform or toward the ramp, this platform shall be at least 3 feet deep and 5 feet wide, and clear of the door frame.
(6) The bottom of the ramp shall have at least 6 feet level run.
(7) If the length of the ramp exceeds 30 feet, level platforms shall be provided at 30 foot intervals, and at turns in the ramp. These platforms shall be at least 32 inches wide (in all cases the width of the ramp) by 5 feet long.
This section cited in 31 Pa. Code §243.6 (relating to standards for institutional plan of risk management for hospitals and nursing homes); and 31 Pa. Code §244.3 (relating to standards for institutional plan of risk management for hospitals and nursing homes).