Section 47.121 - Walks

Universal Citation: 34 PA Code ยง 47.121

Current through Register Vol. 54, No. 38, September 21, 2024

There shall be at least one walk serving each of the buildings as set forth in § 47.111 (relating to scope) conforming to the following specifications:

(1) Be at least 48 inches wide with a slope no portion of which is steeper than 5%.

(2) Be of a continuing common surface uninterrupted by steps or abrupt changes in grade.

(3) Blend to a common level whenever the walk crosses other walks, driveways or parking lots.

(4) Have a level platform at the building entrance which it serves and the platform shall be at least 5 feet square if a door swings out on to the platform or toward the walk; the platform shall extend at least 1 foot beyond each side of the doorway.

(5) Have a level platform at least 3 feet deep and 5 feet wide if the door does not swing on to the platform or toward the walk; the platform shall extend at least 1 foot beyond each side of the doorway.

This section cited in 31 Pa. Code §243.6 (relating to standards for institutional plan of risk management for hospitals and nursing homes); and 31 Pa. Code §244.3 (relating to standards for institutional plan of risk management for hospitals and nursing homes).

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.