Section 45.49 - Jump or bed trimmers
Current through Register Vol. 54, No. 38, September 21, 2024
(a) A substantial guard of two-inch-planking or heavy wire mesh shall be placed in front of the saws.
(b) The under part of the saw table shall be enclosed, with suitable hinged doors provided to give access to various parts for lubrication and adjustment. A screen in front shall also be accepted.
(c) When jump saws are operated by one or more foot treadles, a safety block shall be placed under the treadle or treadles while repairs or adjustments are being made. If the saws are controlled by hand levers, a yoke shall be provided to lock all levers when repairs or adjustments are being made.
(d) An iron stirrup shall be fastened to the floor, over the treadle, leaving just sufficient room for the operator to insert his foot above the treadle.
(e) All end saws shall be fenced off or otherwise guarded from contact.