Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 45 - WOODWORKING AND RELATED OPERATIONS
SAWMILLS
Section 45.49 - Jump or bed trimmers

Universal Citation: 34 PA Code ยง 45.49

Current through Register Vol. 54, No. 38, September 21, 2024

(a) A substantial guard of two-inch-planking or heavy wire mesh shall be placed in front of the saws.

(b) The under part of the saw table shall be enclosed, with suitable hinged doors provided to give access to various parts for lubrication and adjustment. A screen in front shall also be accepted.

(c) When jump saws are operated by one or more foot treadles, a safety block shall be placed under the treadle or treadles while repairs or adjustments are being made. If the saws are controlled by hand levers, a yoke shall be provided to lock all levers when repairs or adjustments are being made.

(d) An iron stirrup shall be fastened to the floor, over the treadle, leaving just sufficient room for the operator to insert his foot above the treadle.

(e) All end saws shall be fenced off or otherwise guarded from contact.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.