(a) Shield. The stand of the sawyer shall be protected by a shield at least four feet in height, consisting of iron or steel not less than 1/4 inch thick, or planks 2 inches or more in thickness, or a concrete wall 8 inches or more in thickness.
(b) Emergency stop. Means shall be provided on portable mills so that the sawyer may, in emergency, stop the mill without leaving his stand.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.