Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 43 - TUNNEL CONSTRUCTION AND COMPRESSED AIR WORK
Subchapter A - TUNNEL CONSTRUCTION AND WORK IN COMPRESSED AIR
WORK IN COMPRESSED AIR-GENERAL
Section 43.61 - Medical locks

Universal Citation: 34 PA Code ยง 43.61
Current through Register Vol. 54, No. 38, September 21, 2024

A medical lock shall be established and maintained in connection with all work in compressed air when the maximum pressure exceeds 17 pounds. The locks shall be not less than 5 feet in height and shall be divided into two compartments. Each door shall be provided with a bull's eye and fitted with air valve so arranged to be operated from within and without. The lock shall be kept properly heated, lighted and ventilated, and shall contain a gauge, a telephone and cot. The lock shall be under the control of a physician in charge and there shall be maintained in close proximity a first aid room which shall contain a bathtub and all medical and surgical appliances necessary for first aid in case of accident.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.