Section 43.55 - Lighting
Universal Citation: 34 PA Code ยง 43.55
Current through Register Vol. 54, No. 38, September 21, 2024
(a) All lighting in compressed air chambers shall be by electricity only. If practicable there shall be two independent lighting systems with independent sources of supply.
(b) The exterior of all lamp sockets shall be entirely nonmetallic.
(c) All portable incandescent lamps used shall be guarded by a wire cage large enough to enclose both lamp and socket.
(d) All incandescent lamps shall be so placed that they do not come in contact with any combustible material.
(e) Only heavy insulated or armored wire shall be used.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.