Current through Register Vol. 54, No. 38, September 21, 2024
(a) The code of signals used shall be printed and posted. Posting shall be in a conspicuous place near entrances to work places and in other places as may be necessary to bring the code to the attention of all persons affected by it. The printing and posting of the code shall be in a language necessary to be understood by all persons affected by it.
(b) Effective and reliable signaling devices shall be maintained at all times to give instant communication between the bottom and top of the shaft.
(c) The code for all work in compressed air, when the whistle and repeating rap are used, shall be as follows:
(d) The code for the operation of any car, cage or bucket shall be as follows:
(e) In all cases reply signals repeating the original signals shall be made before proceeding.
(f) Additional signals to meet local conditions may be adopted.
(g) The minimum size of type to be used in notices shall be at least 1 inch in height.