Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 41 - SANITATION
Subchapter A - INDUSTRIAL SANITATION
SPECIAL REQUIREMENTS FOR NEW INSTALLATIONS
Section 41.102 - Toilet rooms
Current through Register Vol. 54, No. 38, September 21, 2024
(a) In toilet rooms, the floor and the baseboard to a height of at least six inches shall be watertight (except for the regular floor drain) and of even surface.
(b) Entrances to toilet rooms for opposite sexes shall be remote from each other.
(c) All partitions separating a toilet room provided for men from a toilet room provided for women shall extend from the floor to the ceiling, and there shall be no direct communication between the toilet rooms either by door or other opening.
(d) Toilet rooms and washrooms shall have a window opening directly to the outside air or shall be provided with artificial ventilation. A skylight shall be deemed the equivalent of a window, if it has fixed or movable louvres.
This section cited in 34 Pa. Code § 41.191 (relating to toilet rooms).