(a) Seats and foot rests of grandstands shall be designed to support, in addition to their own weight, a uniformly distributed live load of 120 pounds per linear foot of seatboard and footrest. Other parts of grandstands shall be designed to support, in addition to their own weight, a uniformly distributed live and impact load according to the back to back distance between seats as follows:
Back to Back of Seats (in inches) | Pounds per Square Foot |
22 | 130 |
23 | 125 |
24 | 120 |
25 | 115 |
26 | 110 |
27 | 105 |
More than 27 | 100 |
(b) Grandstands shall be designed to resist, when occupied, a horizontal swaying force applied to the seats, in a direction parallel to the length of the seats of 24 pounds per linear foot of seats, and in a direction perpendicular to the length of the seats of ten pounds per linear foot of seats. On grandstands supporting chairs these loads shall be applied at a height of 17 inches above the foot rest.
(c) Grandstands able to be used outdoors shall be designed to resist a horizontal wind load on the vertical projection of the stand, applied in any direction, as follows:
(d) Members whose stresses are greater under a partial loading of the stand than under full load, shall be designed to meet the conditions causing the largest stresses.
(e) The design shall remain stable so as not to be overturned by wind or unequal distribution of the live load.