Pennsylvania Code
Title 25 - ENVIRONMENTAL PROTECTION
Part I - Department of Environmental Protection
Subpart D - Environmental Health and Safety
Article V - Radiological Health
Chapter 236 - LOW-LEVEL RADIOACTIVE WASTE MANAGEMENT AND DISPOSAL
Subchapter B - REQUIREMENTS FOR SITING THE REGIONAL DISPOSAL FACILITY
PHASE I SCREENING REQUIREMENTS
Section 236.125 - Seismology

Universal Citation: 25 PA Code ยง 236.125

Current through Register Vol. 54, No. 44, November 2, 2024

(a) Disqualifying criteria. Potentially suitable sites may not be located within 1 mile of an active fault.

(b) Evaluation requirements.

(1) Potentially suitable sites shall be evaluated with respect to regional tectonic history and geologic structure, including stability, faults, folds, joints and fractures.

(2) Capable faults identified in the vicinity of a site shall be evaluated to determine correlation of the fault with recorded or suspect earthquake activity and potential impact on site stability.

(3) Potentially suitable sites shall be evaluated to determine the proximity to known or reported seismic epicenters within 200 miles. The probable seismic risk and impact associated with those epicenters that reported a Mercalli intensity of (IV) or greater shall be evaluated.

This section cited in 25 Pa. Code § 236.101 (relating to scope and applicability); 25 Pa. Code § 236.104 (relating to siting process); 25 Pa. Code § 236.108 (relating to site justification); and 25 Pa. Code § 236.121 (relating to general requirements).

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.