Section 289.532 - General limitations
Current through Register Vol. 54, No. 44, November 2, 2024
(a) The bottom of the subbase of the liner system cannot be in contact with the seasonal high table or perched water table without the use of groundwater pumping systems.
(b) For unconfined aquifers, at least 8 feet shall be maintained between the bottom of the subbase of the liner system and the regional groundwater table. The regional groundwater table may not be artificially lowered.
(c) For confined aquifers, at least 8 feet shall be maintained between the bottom of the subbase of the liner system and the top of the confining layer or the shallowest level below the bottom of the subbase where groundwater occurs as a result of upward leakage from natural or other preexisting causes. The integrity of the confining layer may not be compromised by excavation.
(d) If the approved design plans provide for the placement of an additional adjacent liner, the following apply:
(e) If the approved design plans do not provide for the placement of additional adjacent liner, waste may not be placed within 4 feet of an edge of the liner.
(f) The edge of the liner shall be clearly marked.
This section cited in 25 Pa. Code § 287.114 (relating to interim operational requirements for unpermitted processing or disposal facilities); 25 Pa. Code § 287.116 (relating to interim operational requirements); 25 Pa. Code § 289.512 (relating to liner system and leachate control plan); 25 Pa. Code § 289.521 (relating to limitations); 25 Pa. Code § 289.531 (relating to scope and requirements); and 25 Pa. Code § 299.144 (relating to operating requirements).