Pennsylvania Code
Title 25 - ENVIRONMENTAL PROTECTION
Part I - Department of Environmental Protection
Subpart D - Environmental Health and Safety
Article IX - Residual Waste Management
Chapter 288 - RESIDUAL WASTE LANDFILLS
Subchapter F - ADDITIONAL REQUIREMENTS FOR CLASS III RESIDUAL WASTE LANDFILLS
ADDITIONAL OPERATING REQUIREMENTS-GENERAL
Appendix A

Universal Citation: 25 PA Code § A
Current through Register Vol. 55, No. 13, March 29, 2025

TABLE I

MINIMUM LINER DESIGN STANDARDS

Liner Material Function Minimum Field Thickness (Units as Specified) Liner Density (Tests as Specified) Remarks
Geosynthetics Primary or Secondary Liner 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer. HDPE liners shall be at least 60 MIL.
Geosynthetics Cap 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer.
Natural & Remodeled ClaySecondary Liner, Cap, Composite Component

2 feet

2 feet

1 foot

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%

*

1. Minimum of 30% fines by weight less than 0.074 mm particle size (# 200 sieve).

2. Plasticity Index greater than or equal to 10.3. No coarse fragments greater than 3/4 inch in diameter.

Sodium bentonite & Bentonite-like materials/soil mixtures

Secondary Liner,

Cap, Composite

Component

2 feet

2 feet

1 foot

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%*

1. Minimum of 8% powdered sodium bentonite or manufacturer's recommendations, whichever is greater.

2. No coarse fragments greater than 3/4 inch in diameter.

3. No organic matter.

Geosynthetic Clay Liner (GCL) Composite Component N/A N/A1. Minimum of 3/4 pound of powdered or granular sodium bentonite per square foot.

* Percentage of maximum when using Standard Proctor method of design (Pa. PTM No. 106, Method B).

Cross References

This table cited in 25 Pa. Code § 288.434 (relating to secondary liner); 25 Pa. Code § 288.436 (relating to primary liner); and 25 Pa. Code § 288.439 (relating to surface mined areas).

TABLE II

MINIMUM LINER DESIGN STANDARDS

Liner Material Function Minimum Field Thickness (Units as Specified) Liner Density (Tests as Specified) Remarks
Geosynthetics Liner, Cap 30 mil N/A 1. A greater thickness may be required depending upon the recommendations of the manufacturer. HDPE liners shall be at least 60 MIL.
Natural & Remolded Clay Cap, Composite Component

2 feet

1 foot

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%*

1. Minimum of 30% fines by weight less than 0.074 mm particle size (#200 sieve).

2. Plasticity Index greater than or equal to 10. 3. No coarse fragments greater than 3/4 inch in diameter.

Sodium Bentonite and Bentonite-like materials Cap, Composite Component

2 feet

1 foot

[GREATER THAN EQUAL TO] 90%*

[GREATER THAN EQUAL TO] 90%*

1. Minimum of 8% powdered sodium bentonite or manufacturer's recommendations, whichever is greater.

2. No coarse fragments greater than 3/4 inch in diameter. 3. No organic matter.

Geosynthetic Clay liner (GCL) Composite Component N/A N/A 1. Minimum of 3/4 pound of powdered or granular sodium bentonite.

* Percentage of maximum when using Standard Proctor method of design (Pa. PTM No. 106, Method B).

This table cited in 25 Pa. Code § 288.234 (relating to final cover and grading); 25 Pa. Code § 288.535 (relating to liner); and 25 Pa. Code § 288.538 (relating to surface mined areas).

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.