Oregon Administrative Rules
Chapter 918 - DEPARTMENT OF CONSUMER AND BUSINESS SERVICES, BUILDING CODES DIVISION
Division 400 - SAFETY CODE FOR ELEVATORS
Section 918-400-0675 - Scope of Elevator Work Allowed with Minor Installation Label
Universal Citation: OR Admin Rules 918-400-0675
Current through Register Vol. 63, No. 9, September 1, 2024
(1) Except as expressly provided in this rule, "minor elevator work" does not include modernization work; minor elevator work allowed under the minor label program provided by OAR 918-100-0000 through 918-100-0060 shall be as follows:
(a) Replacement or repair of
elevator signal equipment, including emergency signaling and communications
equipment;
(b) Replacement or
repair of elevator car lighting or fans;
(c) Replacement, repair, or modernization of
elevator car enclosure linings and floor coverings;
(d) Replacement or repair of a reopening
device for power-operated car doors or gates;
(e) Replacement or repair of pressure piping,
piping connections, valves, or fittings;
(f) Replacement or repair of speed
governors;
(g) Replacement or
repair of hydraulic control valves;
(h) Replacement or repair of elevator
entrance assembly; and,
(i)
Installation, replacement, repair, or modernization of cartop controls, door
operators, or security card readers.
(2) Only one type of minor label work listed in section (1) of this rule may be performed on one minor label; for any 30 day period, only one minor label may be used for each elevator at a job site.
Stat. Auth.: ORS 460.085
Stats. Implemented: ORS 460.085
Disclaimer: These regulations may not be the most recent version. Oregon may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.