Oregon Administrative Rules
Chapter 690 - WATER RESOURCES DEPARTMENT
Division 210 - WELL CONSTRUCTION STANDARDS
Section 690-210-0180 - Additional Standards for Driven or Jetted Wells

Universal Citation: OR Admin Rules 690-210-0180
Current through Register Vol. 63, No. 9, September 1, 2024

All drive point wells or jetted wells shall have nonperforated, watertight casing meeting the minimum specifications shown in Table 210-1 and extending a minimum distance of 18 feet below land surface. Drive casing greater than 3-1/2 inches shall comply with the minimum specifications in OAR 690-210-0190. An upper drillhole at least four inches greater in nominal diameter than the permanent casing shall extend at least 18 feet below land surface. The annular space shall be filled with grout. If temporary casing is used during construction, it must be removed during placement of the grout. (See Figure 210-10.)

To view attachments referenced in rule text, click here to view rule.

Statutory/Other Authority: ORS 536.090, ORS 537.505-537.795, ORS 536.027, ORS 536.900 & ORS 537.992

Statutes/Other Implemented: ORS 536.090, ORS 537.505-537.795, ORS 536.900 & ORS 537.992

Disclaimer: These regulations may not be the most recent version. Oregon may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.