Oklahoma Administrative Code
Title 748 - Oklahoma Uniform Building Code Commission
Chapter 20 - Adopted Codes
Subchapter 16 - IPC[®] 2018
Section 748:20-16-7 - IPC[®] 2018 Chapter 2 Definitions
Current through Vol. 42, No. 1, September 16, 2024
Chapter 2 of the Oklahoma adopted IPC® 2018 is adopted with the following modification: The definition of a BUILDING DRAIN has been modified to align with the industry standard where the site sewer (civil) picks up 5 feet outside of the building. This definition has been modified to read: BUILDING DRAIN. That part of the lowest piping of a drainage system that receives the discharge from soil, waste, and other drainage pipes inside and that extends 5 feet (1524 mm) in developed length of pipe beyond the exterior walls of the building and conveys the drainage to the building sewer.
(1) Combined. A building drain that conveys both sewage and storm water or other drainage.
(2) Sanitary. A building drain that conveys sewage only.
(3) Storm. A building drain that conveys storm water or other drainage, but not sewage.