Oklahoma Administrative Code
Title 748 - Oklahoma Uniform Building Code Commission
Chapter 20 - Adopted Codes
Subchapter 16 - IPC[®] 2018
Section 748:20-16-12 - IPC[®] 2018 Chapter 7 Sanitary Drainage
Current through Vol. 42, No. 1, September 16, 2024
Chapter 7 of the Oklahoma adopted IPC® 2018 is adopted with the following modifications:
(1) Section 705.10.2 Solvent cementing. This section has been modified to delete the exceptions for not using primer under certain conditions. This section has been modified to read: 705.10.2 Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F 656 shall be applied. Solvent cement not purple in color and conforming to ASTM D 2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D 2855. Solvent-cement joints shall be permitted above or below ground.
(2) Section 708.1.3 Building drain and building sewer junction. This section has been modified to change the requirement for the cleanout to be located at the junction or from within 10 feet to within 12 feet of the developed length of piping upstream of the junction. This section has been modified to read: 708.1.3 Building drain and building sewer junction. The junction of the building drain and the building sewer shall be served by a cleanout that is located at the junction or within 12 feet (3658 mm) of the developed length of piping upstream of the junction. For the requirements of this section, the removal of the water closet shall not be required to provide cleanout access.