Oklahoma Administrative Code
Title 310 - Oklahoma State Department of Health
Chapter 257 - Food Establishments
Subchapter 11 - Physical Facilities
Section 310:257-11-31 - Lighting, intensity

Universal Citation: OK Admin Code 310:257-11-31

Current through Vol. 42, No. 1, September 16, 2024

The light intensity shall be:

(1) At least 108 lux (10 foot candles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning;

(2) At least 215 lux (20 foot candles):

(A) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption;

(B) Inside equipment such as reach-in and under-counter refrigerators;

(C) At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and

(3) At least 540 lux (50 foot candles) at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.

Added at 23 Ok Reg 2358, eff 6-25-06; Amended at 28 Ok Reg 2289, eff 11-1-11

Disclaimer: These regulations may not be the most recent version. Oklahoma may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.