[Comment: When a reference is made within this rule to a federal statutory provision, an industry consensus standard, or any other technical publication, the specific date and title of the publication as well as the name and address of the promulgating agency are listed in rule 4101:8-44-01 of the Administrative Code. The application of the referenced standards shall be limited and as prescribed in section 102.5 of rule 4101:8-1-01 of the Administrative Code.]
Section 2501
PLUMBING SYSTEMS
2501.1
Plumbing systems.
The provisions of the "Ohio Plumbing Code" as
referenced in Chapter 44 shall be incorporated herein, except as modified in
Section 2501.1.1, and shall govern the installation, testing and operation of
the plumbing in buildings within the scope of this code.
2501.1.1
Modifications to the "Ohio Plumbing
Code".
The following
sections of the "Ohio Plumbing Code" shall be deleted and replaced with the
following language:
417.5.2
Shower lining requirements.
Floors under shower compartments, except where
prefabricated receptors have been provided, shall be lined and made water tight
utilizing material complying with Sections 417.5.2.1 through 417.5.2.5. Such
liners shall turn up on all sides at least 2 inches (51 mm) above the finished
threshold level. Liners shall be recessed and fastened to an approved backing
so as not to occupy the space required for wall covering, and shall not be
nailed or perforated at any point less than 1 inch (25 mm) above the finished
threshold. Liners shall be pitched one-fourth unit vertical in 12 units
horizontal (2-percent slope) and shall be sloped toward the fixture drains and
be securely fastened to the waste outlet at the seepage entrance, making a
water-tight joint between the liner and the outlet.
Exceptions:
1.
Floor
surfaces under shower heads provided for rinsing laid directly on the ground
are not required to comply with this section.
2.
Where a
sheet-applied, load-bearing, bonded, waterproof membrane is installed as the
shower lining, the membrane shall not be required to be
recessed.
1002.4
Trap seals.
Each fixture trap shall have a liquid seal of not less than
2 inches (51 mm) and not more than 4 inches (102 mm), or deeper for special
designs relating to accessible fixtures. Where a trap seal is subject to loss
by evaporation, a trap seal primer valve shall be installed. Trap seal primer
valves shall connect to the trap at a point above the level of the trap seal. A
trap seal primer valve shall conform to ASSE 1018 or ASSE 1044.
Exceptions:
1.
Where a
trap is supplied with water on a regular basis, a trap seal primer valve shall
not be required.
2.
A trap seal primer valve is not required in
garage floor drains in one-, two- and three-family
dwellings.
Replaces: 4101:8-25-01
Disclaimer: These regulations may not be the most recent version. Ohio may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.