Ohio Administrative Code
Title 3701:1 - Radiation Control
Chapter 3701:1-52 - Licensing and Safety Requirements for Irradiators
Section 3701:1-52-23 - Inspection and maintenance
Universal Citation: OH Admin Code 3701:1-52-23
Current through all regulations passed and filed through March 18, 2024
(A) The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
(1) Operability of each aspect of the access
control system required by rule
3701:1-52-08 of
the Administrative Code.
(2)
Functioning of the source position indicator required by paragraph (B) of rule
3701:1-52-12
of the Administrative Code.
(3)
Operability of the radiation monitor for radioactive contamination in pool
water required by paragraph (B) of rule
3701:1-52-22
of the Administrative Code using a radiation check source, if applicable.
(4) Operability of the over-pool
radiation monitor at underwater irradiators as required by paragraph (B) of
rule
3701:1-52-11
of the Administrative Code.
(5)
Operability of the product exit monitor required by paragraph (A) of rule
3701:1-52-11
of the Administrative Code.
(6)
Operability of the emergency source return control required by paragraph (C) of
rule
3701:1-52-12
of the Administrative Code.
(7) A
visual inspection of the leak-tightness of systems through which pool water
circulates.
(8) Without turning
extinguishers on, operability of the heat and smoke detectors and extinguisher
system required by rule
3701:1-52-10 of
the Administrative Code.
(9)
Operability of the means of pool water replenishment required by paragraph (C)
of rule
3701:1-52-13 of
the Administrative Code.
(10)
Operability of the indicators of high and low pool water levels required by
paragraph (D) of rule
3701:1-52-13 of
the Administrative Code.
(11)
Operability of the intrusion alarm required by paragraph (I) of rule
3701:1-52-08 of
the Administrative Code, if applicable.
(12) Functioning and wear of the system,
mechanisms, and cables used to raise and lower sources.
(13) Condition of the barrier to prevent
products from hitting the sources or source mechanism as required by rule
3701:1-52-14
of the Administrative Code.
(14)
Amount of water added to the pool to determine if the pool is leaking.
(15) Electrical wiring on required
safety systems for radiation damage.
(16) Pool water conductivity measurements and
analysis as required by paragraph (B) of rule
3701:1-52-24 of
the Administrative Code.
(B) Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.
Five Year Review (FYR) Dates:
10/25/2016 and
10/15/2021
Promulgated
Under: 119.03
Statutory
Authority: 3748.04
Rule
Amplifies: 3748.04
Prior
Effective Dates: 10/20/2002, 10/8/07
Disclaimer: These regulations may not be the most recent version. Ohio may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.