Ohio Administrative Code
Title 3701:1 - Radiation Control
Chapter 3701:1-49 - Licensing and Safety Requirements for Well Logging
Section 3701:1-49-07 - Leak testing of sealed sources
Current through all regulations passed and filed through March 18, 2024
(A) Each licensee who uses a sealed source shall have the source tested for leakage
. The licensee shall keep a record of leak test results in units of microcuries and retain the record for inspection by the director for three years after the leak test is performed.
(B) The wipe of a sealed source must be performed using a leak test kit or method approved by the director, the United States nuclear regulatory commission or an agreement state. The wipe sample must be taken from the nearest accessible point to the sealed source where contamination might accumulate. The wipe sample must be analyzed for radioactive contamination. The analysis must be capable of detecting the presence of one hundred eighty-five becquerels ( 0.005 microcurie) of radioactive material on the test sample and must be performed by a person approved by the director, the United States nuclear regulatory commission or an agreement state to perform the analysis.
(C) Sealed sources must be tested at the following frequencies:
(D) If a sealed source is found to be leaking the licensee shall:
(E) The following sealed sources are exempt from the periodic leak test requirements set out in paragraphs (A) to (D) of this rule:
Five Year Review (FYR) Dates:
03/28/2017 and
03/15/2022
Promulgated
Under: 119.03
Statutory
Authority: 3748.04
Rule
Amplifies: 3748.04
Prior
Effective Dates: 10/20/2002, 10/8/07,
9/1/12