Ohio Administrative Code
Title 3701:1 - Radiation Control
Chapter 3701:1-48 - Licensing and Safety Requirements for Industrial Radiography
Section 3701:1-48-20 - Radiation surveys

Universal Citation: OH Admin Code 3701:1-48-20

Current through all regulations passed and filed through March 18, 2024

The licensee shall:

(A) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of rule 3701:1-48-08 of the Administrative Code.

(B) Using a survey instrument meeting the requirements of paragraph (A) of this rule, conduct a survey of the radiographic exposure device and the guide tube after each exposure when approaching the device or the guide tube. The survey must determine that the sealed source has returned to its shielded position before exchanging films, repositioning the exposure head, or dismantling equipment.

(C) Conduct a survey of the radiographic exposure device with a calibrated radiation survey instrument any time the source is exchanged and whenever a radiographic exposure device is placed in a storage area (as defined in rule 3701:1-48-01 of the Administrative Code), to ensure that the sealed source is in its shielded position.

(D) Maintain records in accordance with paragraph (L) of rule 3701:1-48-23 of the Administrative Code.

Five Year Review (FYR) Dates: 04/04/2016 and 04/01/2021
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.06, 3748.07
Prior Effective Dates: 10/20/2002, 3/22/07

Disclaimer: These regulations may not be the most recent version. Ohio may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.