Ohio Administrative Code
Title 1501:10 - Division of Mineral Resources Management - Mine Safety
Chapter 1501:10-2 - Diesel Equipment in Underground Coal Mines
Section 1501:10-2-11 - Fire suppression for equipment and transportation
Current through all regulations passed and filed through September 16, 2024
(A) Fire suppression systems for diesel-powered equipment and fuel transportation units are subject to the provisions of this rule.
(B) The fire suppression system shall be an automatic multipurpose dry-powder type fire suppression system suitable for the intended application and listed or approved by a nationally recognized independent testing laboratory , and meet the following installation standards:
(C) The fire suppression system shall provide automatic fire detection and suppression for all of the following:
(D) The fire suppression system shall include a fire alarm and system fault annunciator that can be seen and heard by the equipment operator.
(E) The fire suppression system shall provide for automatic engine shutdown when the alarm alerts the operator. Engine shutdown and discharge of suppressant agent may be delayed for a maximum of fifteen seconds after the fire alarm annunciator alerts the operator.
(F) Manual actuators. At least two manual actuators are to be provided with at least one manual actuator at each end of the equipment. If the equipment is provided with an operator's compartment, one of the mechanical actuators is to be located in the compartment within easy reach of the operator. For stationary equipment, the two manual actuators are to be located with at least one actuator on the stationary equipment and at least one actuator a safe distance away from the equipment, and in intake air.