Ohio Administrative Code
Title 1301:3 - Division of Industrial Compliance
Chapter 1301:3-4 - Historical Boilers
Section 1301:3-4-05 - Repairs and alterations

Universal Citation: OH Admin Code 1301:3-4-05

Current through all regulations passed and filed through September 16, 2024

(A) All welded repairs or alterations to any historical boiler subject to inspection in accordance with sections 4104.32 to 4104.37 of the Revised Code shall be made by a person certified as a welder in accordance with Section IX of the 2004 edition of the American society of mechanical engineers (ASME) Boiler and Pressure Vessel Code, entitled welding and brazing qualifications, published July 1, 2004, a publication of general availability in the industry.

(B) All welded or riveted repairs or any alteration to any historical boiler subject to inspection in accordance with sections 4104.32 to 4104.37 of the Revised Code shall be made using the materials as shown on the following table:

Materials for welded or riveted repairs and alterations

Application

Material Specification

Boiler Tubes and Flues, Arch Tubes, Superheated Units

SA-178 Grade A Tube, SA-192 Tube, SA 210 Tube

Boiler and Firebox Plate

SA-285 Grade C Plate, SA 515 Plate, SA 516 Plate, SA-203 Plate, SA-204 Plate

Staybolts

SA-675 Bar, SA-36 Bar, ASTM A-31-95 Bar

Staybolt Sleeves and Caps

SA-105 Forged Pipe Fittings, SA-675 Bar

Boiler Braces

SA-675 Bar, SA-36 Bar

Rivets

SA-675 Bar, ASTM A-31-95 Bar

Forged Parts and Fittings

SA-105 Forged Pipe Fittings, SA-181 Forged Pipe Fittings

Pressure Retaining Steel Castings

SA-216 Steel Casting, SA-217 Steel Casting

Hollow Cylindrical Pressure Retaining Parts

SA-105 Forged Pipe Fittings, SA-675 Bar

Superheater Unit Bolts and Nuts

SA-193 Bolts, SA-194 Nuts

Pipe Flanges

SA-181 Forged Pipe Fittings, SA-105 Forged Pipe Fittings

Pipes

SA-106 Pipe, SA-53 Seamless Pipe

Bronze Castings and Washout Plugs

SB-61 Bronze Cast Fittings, SB-62 Bronze Cast Fittings

(C) All welded or riveted repairs or any alteration to any historical boiler subject to inspection in accordance with sections 4104.32 to 4104.37 of the Revised Code shall be made in conformity with or shall exceed generally accepted engineering standards in place at the time of original construction or current standards.

Disclaimer: These regulations may not be the most recent version. Ohio may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.