Current through Supplement No. 395, January, 2025
In addition to the requirements of section 33.1-20-01.1-11 and chapter 33.1-20-04.1, the owner or operator of an industrial waste landfill or a special waste landfill, excluding CCR landfills subject to chapter 33.1-20-08, shall comply with the design, construction, and operating standards as follows:
1. On all areas of the landfill where final cover or additional solid waste will not be placed within six months, eight inches [20.3 centimeters] or more of compacted clay-rich soil material, similar material, or a synthetic cover must be placed to prevent ponding of surface water, to minimize infiltration of surface water, and to control windblown dust.
2. Solid waste disposal in industrial waste landfills and special waste landfills must be limited to those wastes identified in the permit application or permit. Regulated infectious waste, used oil as a free liquid, and hazardous waste may not be accepted for disposal at the landfill. TENORM waste may only be accepted under the provisions of chapter 33.1-20-11.
3. All solid wastes deposited at the landfill must be spread and compacted as densely as practicable to minimize waste volume and promote drainage of surface water.
4. Any new or lateral expansion of an industrial waste landfill or special waste landfill must be designed with an appropriate hydraulic barrier and leachate management system capable of collecting and removing leachate and contaminated surface water within the disposal unit.
General Authority: NDCC 23.1-03-04, 23.1-08-03; S.L. 2017, ch. 199, § 1
Law Implemented: NDCC 23.1-03-03, 23.1-03-04, 23.1-08-03, 23.1-08-09; S.L. 2017, ch. 199, §§ 18, 23