North Dakota Administrative Code
Title 33.1 - Department of Environmental Quality
Article 33.1-14 - NORTH DAKOTA BOILER RULES
Chapter 33.1-14-11 - HOBBY BOILER OPERATOR LICENSING
Section 33.1-14-11-07 - Hobby boiler operation

Current through Supplement No. 394, October, 2024

1. Notwithstanding any other provision of this section and with the exception of the operation of miniature boilers, two licensed operators or a licensed operator and an apprentice operator must be in attendance on a hobby boiler during a parade or plowing demonstration or during belt operation. At least one licensed operator must be in attendance on a hobby boiler at all other times except when it is considered safe for a hobby boiler operator to leave the hobby boiler as described in subsection 2.

2. A hobby boiler operator is required to be in attendance on a hobby boiler any time the steam pressure is above fifteen pounds per square inch [103.42 kilopascals] gauge and rising unless all of the following conditions are met:

a. The water is above the one-third level in the gauge glass;

b. The fire is extinguished or banked;

c. All draft doors are closed;

d. The main steam outlet valve or dome valve is closed; and

e. The boiler pressure is at least twenty pounds per square inch [137.90 kilopascals] gauge below the safety valve set pressure and the boiler pressure is decreasing.

General Authority: NDCC 23.1-16

Law Implemented: NDCC 23.1-16

Disclaimer: These regulations may not be the most recent version. North Dakota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.