North Carolina Administrative Code
Title 21 - OCCUPATIONAL LICENSING BOARDS AND COMMISSIONS
Chapter 23 - IRRIGATION CONTRACTORS'
Section .0400 - IRRIGATION DESIGN MINIMUM STANDARDS
Section 23 .0405 - MICROIRRIGATION

Universal Citation: 21 NC Admin Code 23 .0405

Current through Register Vol. 39, No. 6, September 16, 2024

For zones with microirrigation, when designing an irrigation system, an irrigation contractor shall:

(1) provide a means of filtration at the master valve to remove particulate matter;

(2) use separate microirrigation zones where differing plant water requirements and root zone depths make such zones practical;

(3) specify pressure-compensating devices to improve overall uniformity;

(4) specify pressure regulation upstream from the drip/microirrigation components to anticipate periodic increases in the pressure of municipal or community water sources when there is flushing or other maintenance on the water supply system. Pressure regulating devices may be omitted only when the maximum possible pressure is known to be lower than the maximum allowable pressure for all drip/microirrigation components; and

(5) use air release valves to minimize ingestion of soil and other contaminants into the emitters.

Authority G.S. 89G-5;
Eff. July 1, 2011;
Pursuant to G.S. 150B-21.3A, rule is necessary without substantive public interest Eff. September 22, 2014;
Amended Eff. November 1, 2016.

Disclaimer: These regulations may not be the most recent version. North Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.