North Carolina Administrative Code
Title 21 - OCCUPATIONAL LICENSING BOARDS AND COMMISSIONS
Chapter 23 - IRRIGATION CONTRACTORS'
Section .0300 - IRRIGATION RECORD DRAWING MINIMUM STANDARDS
Section 23 .0301 - IRRIGATION RECORD DRAWING
Universal Citation: 21 NC Admin Code 23 .0301
Current through Register Vol. 39, No. 6, September 16, 2024
(a) All irrigation record drawings shall:
(1) be
drawn to portray the site;
(2) be
legible and reproducible;
(3)
include the surrounding development (e.g. building edges, walks, walls, roads),
irrigated areas, turf areas, and planted areas; and
(4) show the sprinkler system,
microirrigation system, or both as installed and include the location of:
(a) emergency shut-off valve(s);
(b) water source(s);
(c) backflow devices;
(d) all types of valves;
(e) all wire splices;
(f) all wire paths;
(g) controllers;
(h) all sensors;
(i) all grounding location(s) and
type(s);
(j) all pumps;
(k) all filters;
(l) all quick couplers or any other water
connection points; and
(m) all main
line piping.
(b) All manual and automatic valve locations shall be shown with distances to permanent reference points so that they may be located in the field. Permanent reference points are buildings, drainage inlets, sidewalks, curbs, light poles, and other permanent, immovable objects.
(c) The irrigation record drawings shall be labeled "Record Drawings".
Authority
G.S.
89G-5(15);
Eff.
July 1, 2011;
Pursuant to
G.S.
150B-21.3A, rule is necessary without
substantive public interest Eff. September 22, 2014;
Amended Eff.
November 1, 2016.
Disclaimer: These regulations may not be the most recent version. North Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.