North Carolina Administrative Code
Title 15A - Environmental Quality
Chapter 13 - SOLID WASTE MANAGEMENT
Subchapter B - SOLID WASTE MANAGEMENT
Section .0500 - DISPOSAL SITES
Section 13B .0539 - ENGINEERING PLAN FOR C&DLF FACILITIES
Current through Register Vol. 38, No. 18, March 15, 2024
(a) Purpose. The engineering plan that is required to be submitted in accordance with Rule .0535 of this Section shall incorporate the detailed plans and specifications relative to the design and performance of the C&DLF's containment and environmental control systems. The engineering plan shall set forth the design parameters and construction requirements for the components of the C&DLF's systems, shall meet the requirements of this Rule, and shall establish the responsibilities of the design engineer. The engineered components shall be described in Rule .0540 of this Section. (b) Responsibilities of the design engineer. The engineering plan shall be prepared by a licensed professional engineer if required by G.S. 89C. The design engineer shall incorporate a statement certifying this fact and bearing his or her seal of registration.
(c) Scope. An engineering plan shall be prepared for the proposed area of development that provides no less than five years of operating capacity and no more than the total facility capacity, consistent with the development phases and design criteria defined in the facility plan. The engineering plan shall contain a report and a set of drawings that represent the engineering design in accordance with Paragraphs (d) and (e) of this Rule.
(d) An engineering report shall contain:
(e) Engineering drawings shall illustrate:
(f) The engineering plan shall also describe and illustrate additional engineering features and details including the cap system, leachate collection system, and base liner system, if present. A leachate collection system and a liner system shall be required pursuant to G.S. 130A-295.6 in accordance with the effective dates and applicability requirements in S.L. 2007-550 s. 9.(b) and S.L. 2013-413 s. 59.1 as amended by S.L. 2013-410 s. 47.6. Cap systems, leachate collection systems, leachate storage, and base liner systems shall be in accordance with Rules .1620 and .1621 of this Subchapter.
Authority
G.S.
130A-294;
Eff. January 1,
2007;
Readopted Eff. September 16,
2021.