(a) Electric generating units. Emissions of NOx from any fossil fuel-fired stationary boiler, combustion turbine, or combined cycle system permitted after October 31, 2000, serving a generator with a nameplate capacity greater than 25 megawatts electrical and selling any amount of electricity shall meet the applicable requirement:
(b) Boilers and combustion turbines. Emissions of NOx from any fossil fuel-fired stationary boiler, combustion turbine, or combined cycle system having a maximum design heat input greater than 250 million Btu per hour permitted after October 31, 2000, and not regulated under Paragraph (a) of this Rule, shall meet the applicable requirement:
(c) Internal combustion engines. The following reciprocating internal combustion engines permitted after October 31, 2000, shall comply with the applicable requirements in 15A NCAC 02D .1423 if the engine is not regulated by 15A NCAC 02D .0530 or 02D .0531:
If the engine is regulated by 15A NCAC 02D .0530, it shall comply with the requirements of 15A NCAC 02D .1423 or the best available control technology requirements of 15A NCAC 02D .0530, whichever requires the greater degree of reduction. If the engine is regulated by 15A NCAC 02D .0531, it shall comply with lowest achievable emission rate technology requirements of 15A NCAC 02D .0531.
(d) Monitoring. The owner or operator of a source subject to this Rule, except for internal combustion engines, shall show compliance using a continuous emission monitor that meets the requirements of 15A NCAC 02D .1404(d). Internal combustion engines shall comply with the monitoring requirements in 15A NCAC 02D .1423. Monitors shall be installed before the first ozone season in which the source will operate and shall be operated each day during the ozone season that the source operates.
Authority
G.S.
143-215.3(a)(1);
143.215.107(a)(5); 143.215.107(a)(7); 143.215.107(a)(10);
Temporary
Adoption Eff. August 1, 2001; November 1, 2000;
Eff. July 18,
2002;
Amended Eff. June 1, 2004;
Temporary Amendment
Eff. December 31, 2008(this amendment replaces the amendment approved by RRC on
May 15, 2008);
Amended Eff. September 29, 2009(amendment approved
by RRC on May 15, 2008);
Readopted Eff. October 1,
2020;
Amended Eff. October 1,
2022.