North Carolina Administrative Code
Title 15A - Environmental Quality
Chapter 02 - ENVIRONMENTAL MANAGEMENT
Subchapter D - AIR POLLUTION CONTROL REQUIREMENTS
Section .0500 - EMISSION CONTROL STANDARDS
Section 02D .0535 - EXCESS EMISSIONS REPORTING AND MALFUNCTIONS
Current through Register Vol. 39, No. 6, September 16, 2024
(a) For this Rule the following definitions apply:
(b) This Rule does not apply to sources to which 15A NCAC 02D .0524, 02D .1110, or .1111 applies unless excess emissions exceed an emission limit established in a permit issued under 15A NCAC 02Q .0700 that is more stringent than the emission limit set by 15A NCAC 02D .0524, 02D .1110 or 02D .1111.
(c) Any excess emissions that do not occur during start-up or shut-down are considered a violation of the appropriate rule unless the owner or operator of the source of excess emissions demonstrates to the Director, that the excess emissions are the result of a malfunction. To determine if the excess emissions are the result of a malfunction, the Director shall consider, along with any other pertinent information, the following:
(d) All electric utility boiler units shall have a malfunction abatement plan approved by the Director as satisfying the requirements of Subparagraphs (1) through (3) of this Paragraph. In addition, the Director may require any other source to have a malfunction abatement plan approved by the Director as satisfying the requirements of Subparagraphs (1) through (3) of this Paragraph. If the Director requires a malfunction abatement plan for a source other than an electric utility boiler, the owner or operator of that source shall submit a malfunction abatement plan within 60 days after receipt of the Director's request. The malfunction plans of electric utility boiler units and of other sources required to have them shall be implemented when a malfunction or other breakdown occurs. The purpose of the malfunction abatement plan is to prevent, detect, and correct malfunctions or equipment failures that could result in excess emissions. A malfunction abatement plan shall contain:
(e) The owner or operator of any source required by the Director to have a malfunction abatement plan shall submit a malfunction abatement plan to the Director within six months after it has been required by the Director. The malfunction abatement plan and any amendment to it shall be reviewed by the Director or his designee. If the plan carries out the objectives described by Paragraph (d) of this Rule, the Director shall approve it. If the plan does not carry out the objectives described by Paragraph (d) of this Rule, the Director shall disapprove the plan. The Director shall state his reasons for his disapproval. The person who submits the plan shall submit an amendment to the plan to satisfy the reasons for the Director's disapproval within 30 days of receipt of the Director's notification of disapproval. Any person having an approved malfunction abatement plan shall submit to the Director for his approval amendments reflecting changes in any element of the plan required by Paragraph (d) of this Rule or amendments when requested by the Director. The malfunction abatement plan and amendments to it shall be implemented within 90 days upon receipt of written notice of approval.
(f) The owner or operator of a source of excess emissions that last for more than four hours and that results from a malfunction, a breakdown of process or control equipment or any other abnormal conditions, shall:
(g) Start-up and shut-down. Excess emissions during start-up and shut-down are considered a violation of the applicable rule if the owner or operator cannot demonstrate that the excess emissions are unavoidable. To determine if excess emissions are unavoidable during startup or shutdown the Director shall consider the items listed in Subparagraphs (c)(1), (c)(3), (c)(4), (c)(5), and (c)(7) of this Rule along with any other pertinent information. The Director may specify for a particular source the amount, time, and duration of emissions allowed during start-up or shut down if necessary to limit excess emissions and protect the NAAQS. The owner or operator shall, to the extent practicable, operate the source and any associated air pollution control equipment or monitoring equipment in a manner consistent with best practicable air pollution control practices to minimize emissions during start-up and shut-down.
Authority
G.S.
143-215.3(a)(1);
143-215.107(a)(4);
143-215.107(a)(5);
Eff. March 1, 1983;
Amended Eff. June 1, 2008; April 1, 2001; July
1, 1998; July 1, 1996; October 1, 1991; May 1, 1990; April 1, 1986; July 1,
1984;
Amendment approved by RRC October 20, 2016 with a delayed
effective date. Effective date delayed by Codifier upon May 15, 2018 request
from the Environmental Management Commission. Rendered void May 28, 2020 by
final action of the EPA withdrawing SIP Call for North Carolina, 85 Fed. Reg.
23700 (April 28, 2020) and the State's withdrawal of its SIP submittal to EPA
on August 25, 2022;
Readopted Eff. November 1,
2020.