Section 11 R07-29 - WATER METER ACCURACY
Current through Register Vol. 39, No. 6, September 16, 2024
(a) Installation Test. - Every water service meter, whether new or repaired, shall be in good order and shall be correct to within 2% fast or slow before being installed for the use of any customer.
(b) Meter Test Flows. - The following test rates are recommended for conducting test:
It is recommended that no less than three rates of flow be used.
Meter |
Allowable Range Test Flow Gallons per Minute |
Recommended Test Rate Flow |
Gallons per Minute |
||
Size |
Min. |
Max. |
Min. |
Med. |
Max. |
1 1/2 |
5 |
100 |
5 |
25 |
100 |
2 |
8 |
160 |
8 |
40 |
160 |
3 |
16 |
300 |
15* |
100 |
300 |
4 |
28 |
500 |
15* |
250 |
500 |
6 |
48 |
1000 |
20* |
500 |
1000 |
*Note - A meter failing to register 5% of the water passed at those rates marked * should not be installed without correction.
(c) Method of Testing. - All tests to determine the accuracy of registration of any water service meter shall be made with suitable testing instruments.