New York Codes, Rules and Regulations
Title 21 - Miscellaneous
Chapter XI - New York State Energy Research And Development Authority
Part 508 - Green Residential Building Program
Section 508.4 - Green residential building standards
Current through Register Vol. 46, No. 12, March 20, 2024
For purposes of the program, green residential building standards shall mean the use of design and building techniques sufficient:
(a)
(b)
Table 1: Lamps and Lamp/Ballast Fixtures: Efficacy Requirements
Part A: Bare, Covered, Globe, and Outdoor Reflector CFL Testing Requirements
Criteria |
Requirements |
Test Procedure for Determining Efficacy |
|
Lamp Power (Watts) and Configuration | Minimum Efficacy: Lumens/watt (Based on initial lumen data) | ||
Efficacy requirements (Medium screw-base) | Efficacy requirements (Candelabra screwbase) | ||
Bare Lamp (Fixed Light Output): | |||
Lamp Power < 10 | 50 | 50 | |
10 < Lamp Power < 15 | 55 | 55 | |
15 d Lamp Power | 65 | NA | |
Bare Lamp |
LM66-00 IESNAa for lumen output and efficacy. |
||
(Dimmable/2-way/3-way): | |||
Lamp Power < 15 | 50 | 50 | |
Lamp Power e 15 | 60 | NA | |
Covered Lamp (no reflector): | |||
Lamp Power < 7 | 40 | 35 | |
7 < Lamp Power < 15 | 45 | 45 | |
15 < Lamp Power < 25 | 50 | NA | |
Lamp Power > 25 | 60 | NA | |
Outdoor Reflectors: | |||
Lamp Power < 20 | 33 | NA | |
Lamp Power > 20 | 40 | NA |
Part B: Reflector CFLs for Recessed Downlights/Indoor Use Testing Requirements
Criteria Item and Submission |
Requirement |
Test Procedure for Determining Efficacy |
Lamp Power (Watts) and Configuration Reflectors: | Minimum Efficacy: Lumens/watt (Based on initial lumen data) | LM66-00 IESNAa - for lumen output and efficacy. |
Lamp Power < 20 | 33 | |
Lamp Power > 20 | 40 |
Part C: Combined Lamp and Ballast Efficacy Requirements
Performance Characteristics |
Requirements |
Test Procedure for Determining Efficacy |
System Efficacy Per Lamp Ballast Platform in Lumens Per Watt (LPW) | [GREATER THAN EQUAL TO] 50 LPW for all lamp types below 30 total listed lamp watts. | IESa LM-9 and LM-66-00 IESNAa; ANSIb C82.2 - 2002 |
[GREATER THAN EQUAL TO] 60 LPW for all lamp types that are < 24 inches and > 30 total listed lamp watts. | ||
[GREATER THAN EQUAL TO] 70 LPW for all lamp types that are > 24 inches and > 30 total listed lamp watts. |
a IES and IESNA means the Illuminating Engineering Society (of North America)
b ANSI means the American National Standards Institute
Table 2: Minimum Energy Efficiency Requirements for Dishwashers
Dishwasher Type |
Standard as of August 11, 2009 |
Standard as of July 1, 2011 |
Test Procedure for Determining Efficiency Level |
Standard | [LESS THAN EQUAL TO] 324 kWh/year [LESS THAN EQUAL TO] 5.8 gallons/cycle | [LESS THAN EQUAL TO] 307 kWh/year [LESS THAN EQUAL TO] 5 gallons/cycle | 10 CFR 430, Subpart B, Appendix C. |
Compact | [LESS THAN EQUAL TO] 234 kWh/year [LESS THAN EQUAL TO] 4.0 gallons/cycle | [LESS THAN EQUAL TO] 222 kWh/year [LESS THAN EQUAL TO] 3.5 gallons/cycle | 10 CFR 430, Subpart B, Appendix C. |
Table 3: Minimum Efficiency Requirements for Refrigerators, Refrigerator-Freezers, and Freezers
Product Class | Energy Use (kWh per year) |
Refrigerator and refrigerator-freezer with manual defrost | [LESS THAN EQUAL TO] 7.056* AVa + 198.72 |
Refrigerator-freezer with partial automatic defrost | [LESS THAN EQUAL TO] 7.056* AVa + 198.72 |
Top mount freezer without through-the-door ice | [LESS THAN EQUAL TO] 7.84* AVa + 220.8 |
Side mount freezer without through-the-door ice | [LESS THAN EQUAL TO] 3.928* AVa + 406 |
Bottom mount freezer without through-the-door ice | [LESS THAN EQUAL TO] 3.68* AVa + 367.2 |
Top mount freezer with through-the-door ice | [LESS THAN EQUAL TO] 8.16* AVa + 284.8 |
Side mount freezer with through-the-door ice | [LESS THAN EQUAL TO] 8.08* AVa + 324.8 |
Upright freezer with manual defrost | [LESS THAN EQUAL TO] 6.795* AVa + 232.47 |
Upright freezer with automatic defrost | [LESS THAN EQUAL TO] 11.187* AVa + 293.49 |
Chest freezers | [LESS THAN EQUAL TO] 8.892* AVa + 129.33 |
Compact refrigerator and refrigerator-freezer with manual defrost | [LESS THAN EQUAL TO] 8.56* AVa + 239.2 |
Compact refrigerator and refrigerator-freezer with partial automatic defrost | [LESS THAN EQUAL TO] 5.6* AVa + 318.4 |
Compact refrigerator-freezer-automatic defrost with top freezer | [LESS THAN EQUAL TO] 10.16* AVa + 284 |
Compact refrigerator-side mounted freezer with automatic defrost | [LESS THAN EQUAL TO] 6.08* AVa + 400.8 |
Compact refrigerator-bottom mount freezer with automatic defrost | [LESS THAN EQUAL TO] 10.48* AVa + 293.6 |
Compact upright freezers with manual defrost | [LESS THAN EQUAL TO] 7.824* AVa + 200.64 |
Compact upright freezers with automatic defrost | [LESS THAN EQUAL TO] 9.12* AVa + 312.8 |
Compact chest freezer | [LESS THAN EQUAL TO] 8.36* AVa + 121.6 |
a AV (Adjusted Volume) means, for a combination refrigerator-freezer, the volume of the fresh food compartment in cubic feet added to the product of 1.63 multiplied by the freezer volume and, and for a stand-alone freezer, the product of 1.73 multiplied by the freezer volume in cubic feet.
(c) for a residential building of not more than three stories in height above grade, containing four or fewer dwelling units, shall have met or exceeded the additional requirements set forth in section 508.5 of this Part.