New York Codes, Rules and Regulations
Title 18 - DEPARTMENT OF SOCIAL SERVICES
Chapter II - Regulations of the Department of Social Services
Subchapter C - Social Services
Article 2 - Family and Children's Services
Part 418 - Day Care Centers
Subpart 418-2 - Small Day Care Centers
Section 418-2.4 - Fire protection
Current through Register Vol. 46, No. 39, September 25, 2024
(a) Suitable precautions must be taken to eliminate all conditions which may contribute to or create a fire hazard.
(b) Evacuation drills.
(c) Fire detection, alarm and firefighting equipment appropriate to the type of building construction, size, height and occupancy must be provided, maintained and operate as designed.
(d) All fire alarm and detection systems must be inspected, tested and maintained in accordance with the applicable requirements of the Fire Code and Building Code of New York State or other applicable fire and building codes when the Fire Code and Building Code of New York State is not applicable.
(e) All fire suppression equipment and systems must be tested and maintained in accordance with the applicable requirements of the Fire Code and Building Code of New York State or other applicable fire and building codes when the Fire Code and Building Code of New York State is not applicable.
(f) Adequate means of egress must be provided. Children may be cared for only on such floors as are provided with readily accessible alternate means of egress to other floors, in the case of fire-resistant buildings, and to the outside in the case of non-fire-resistant buildings.
(g) Trash, garbage and combustible materials must not be stored in the furnace room or in rooms or outdoor areas adjacent to the facility that are ordinarily occupied by or accessible to children.
(h) The provider must conduct monthly inspections of the premises to observe possible fire or safety hazards. Any such hazard must be corrected immediately.
(i) A record of all inspections and all corrections must be maintained at the program, or at a central location available for review upon request.
(j) Steam or hot water boilers must be inspected and approved in accordance with the requirements of the New York State Department of Labor by an inspector from the New York State Department of Labor, or by an insurance company which is licensed to write boiler insurance in the State. All other fuel burning heating systems and equipment and boilers not subject to the New York State Department of Labor requirements must be serviced by a heating contractor once every 24 months.
(k) Rooms containing boilers, fuel burning furnaces or other fuel burning heating equipment must be constructed using a minimum of one-hour fire resistant materials or materials of a greater fire resistance when required by Fire Code and Building Code of New York State, or other applicable fire and building codes when the Fire Code and Building Code of New York State is not applicable.