New York Codes, Rules and Regulations
Title 17 - DEPARTMENT OF TRANSPORTATION
Chapter VI - Transportation Regulations
Subchapter F - Railroad And Street Railroad Corporations
Article 2 - Safety
Part 922 - Locomotive Boilers And Steam Reservoirs
Section 922.4 - Maximum allowable stress on stays and braces

Current through Register Vol. 46, No. 39, September 25, 2024

For locomotives, the maximum allowable stress per square inch of net cross-sectional area on fire box and combustion chamber stays, shall be 7,500 pounds. The maximum allowable stress per square inch of net cross-sectional area on round, rectangular, or gusset braces shall be 9,000 pounds.

Disclaimer: These regulations may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.