New York Codes, Rules and Regulations
Title 16 - DEPARTMENT OF PUBLIC SERVICE
Chapter IV - STEAM UTILITIES
Subchapter A - Service
Part 400 - Installation Of House Service Equipment, Operating Conditions, And Testing Of Meters And Of Steam Quality By Corporations Having 1,000 Installed Custom
Section 400.4 - Referee tests

Current through Register Vol. 46, No. 12, March 20, 2024

(a) In a referee test, a representative of the commission will seal the meter or meter device involved, and will notify the utility within 24 hours that such meter or device has been sealed.

(b) In a referee test, the seals for the meter or the meter device involved shall be opened only in the presence of a representative of the commission. The meter or meter device shall be tested under the direction of a representative of the commission.

(c) When, in a referee test, the percentage registration of a meter is found to be more than 102 percent, no charge shall be made for such test. If, however, as a result of such test, the percentage registration of the meter is found to be 102 percent or less, a charge shall be made to the customer by the utility based on the following schedule:

Type of Meter

Capacity or Size

Fee

Condensate 3000 lbs. per hr. or less $ 25.00
Condensate Over 3000 lbs. per hr. 50.00
Area 1 in. 25.00
Area 1½ in. 25.00
Area 2 in. 50.00
Area 3 in. 75.00
Area 4 in. 100.00
Area 6 in. 150.00
Area 8 in. 300.00
Velocity 1 in. 25.00
Velocity 2 in. 25.00
Velocity 3 in. 50.00
Velocity 4 in. 50.00
Head All 100.00

Disclaimer: These regulations may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.