New York Codes, Rules and Regulations
Title 12 - DEPARTMENT OF LABOR
Chapter I - Industrial Board Of Appeals
Subchapter A - The Industrial Code
Part 23 - Protection In Construction, Demolition And Excavation Operations
Subpart 23-8 - Mobile Cranes, Tower Cranes And Derricks
Section 23-8.4 - Special provisions for derricks
Current through Register Vol. 47, No. 12, March 26, 2025
(a) Bracing of foot blocks. The foot blocks of every derrick shall be securely supported and firmly anchored against movement in any direction.
(b) Guys.
(c) Breast-type derricks. Breast-type derricks shall be guyed from both the front and rear. Where front guys are not possible because of derrick operation, provisions shall be made to prevent such derricks from tipping over backward. Breast-type derricks which are operated by hand power shall have hand grips securely and positively fastened to the shaft and a ratchet and pawl shall be provided which will hold any load.
(d) Derrick construction.
(e) Derrick capacity charts.
(f) Derrick boom raising. The boom of any derrick shall not be raised from the level of the surface on which the derrick rests other than by the use of its own hoisting capabilities. The design, construction and length of the boom shall be such that there is no undue stress imposed on the derrick structure or mechanism during such raising operations.