Section 23-2.4 - Flooring requirements in building construction
Universal Citation: 12 NY Comp Codes Rules and Regs § 23-2.4
Current through Register Vol. 47, No. 12, March 26, 2025
(a) Permanent flooring--skeleton steel construction in tiered buildings. The permanent floors of such buildings or other structures shall be installed as soon as possible as the erection of structural steel members progresses. In no case shall there be more than eight stories, floors or equivalent levels or 120 feet, whichever is less, between the erection floor and the uppermost permanent floor.
(b) Temporary flooring--skeleton steel construction in tiered buildings.
(1)
Erection by tower crane or derrick.
(i) The
erection floor shall be covered over the entire surface except for access
openings. Such flooring shall be of the proper strength to support the working
load intended to be imposed thereon. Such temporary flooring shall be laid
tight and secured against movement.
(ii) There shall also be provided a tight and
substantial floor within two stories or 30 feet, whichever is less, below and
directly under that portion of each tier of beams on which any work is being
performed. Such floor shall be of the proper strength to support the working
load intended to be imposed thereon. Such floor shall be constructed of
planking at least two inches thick full size or material of equivalent strength
as a minimum.
(2)
Erection by ground-supported crane. Where erection is being done by means of a
crane operating on the ground, grade or equivalent surface, a tight, secure and
substantial floor shall be installed within two stories or 30 feet, whichever
is less, below and directly under that portion of each tier of beams on which
any work is being performed. Such floor shall consist of planking at least two
inches thick full size or of material of equivalent strength. As an alternative
to such floor, an approved life net installed in compliance with this Part
(rule) may be provided. Any such life net shall be installed and maintained not
more than two stories or 30 feet, whichever is less, below and directly under
that portion of each tier of beams on which any work is being
performed.
(3) High one story
skeleton steel construction. In the erection of one story skeleton steel
buildings or other structures where the clear vertical height of such building
or other structure is 30 feet or more, protection similar to that required for
tiered construction as specified in paragraphs (1) and (2) above shall be
provided.
(c) Flooring--other construction.
(1) In the
erection of any building or other structure having double wood floor or bar
joist construction, the rough flooring shall be completed as the construction
of such building or other structure progresses, including the tier below the
one on which the wood floor joists or bar joists are being installed.
(2) In the construction of a building or
other structure having single wood flooring or any other flooring system, the
floor immediately below the story where the floor joists are being installed
shall be kept covered. Such flooring shall be at least two inches thick full
size or shall be of material of equivalent strength and be laid tight and
secure.
Disclaimer: These regulations may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.