New York Codes, Rules and Regulations
Title 12 - DEPARTMENT OF LABOR
Chapter I - Industrial Board Of Appeals
Subchapter A - The Industrial Code
Part 23 - Protection In Construction, Demolition And Excavation Operations
Subpart 23-1 - General Provisions
Section 23-1.19 - Catch platforms
Current through Register Vol. 47, No. 12, March 26, 2025
(a) General. Catch platforms shall not be used as working platforms, walkways or for the storage of material.
(b) Catch platform construction. Catch platforms where required by this Part (rule) shall comply with the following:
(c) Catch platform enclosures. Except as otherwise permitted by this Part (rule), the open sides of catch platforms shall be provided with a barricade or fence of tight planking at least two inches thick, exterior grade plywood at least three-quarters inch thick or of No. 18 U.S. gage wire screen mesh with openings that will reject a ball one-half inch in diameter. Every such enclosure shall be at least 48 inches in height above the platform with no opening between the bottom of the enclosure and the platform. Supports for a wood enclosure shall be at least two inches by six inches in cross-section and shall be spaced not more than 10 feet apart, center to center.
(d) Catch platform installation. Every catch platform shall be so installed that the inner edge of such catch platform is flush with the wall of the building or other structure on which it is installed.